VIC-D100 Series Digital Mass Flow Controller Description VIC-D145 VIC-D150 Flow Range (N 2 Equivalent) 400 ~ 1,000 slm 1,000 ~ 2,500 slm Flow Control Range 2 ~ 100% of Full Scale Accuracy ≤ ± 2% of Full Scale Response Time ≤ 2 sec (2 ~ 10%) ≤ 1.5 sec (10 ~ 100%) Linearity ≤ ± 0.2% of Full Scale Repeatability ≤ ± 0.2% of Full Scale Value Type Normally Closed Solenoid Seal Type Elastomer (Viton ® , Viton-ETP ® , Kalrez ® , etc.) Input / Output Signal Analog Mode: 0 ~ 5VDC or 4 ~ 20mA Digital Mode: RS-485 (D-NET Possible) Power Supply +24VDC (+15VDC products are also available.) Recommended Operating Temperature Range 15 ~ 35℃ Warm-up Time 30 min Electrical Connection D-SUB 9P MALE (D-NET: M12 5P MALE) Weight (STS) 6.2 kg 7.8 kg Weight (AL) 2.98 kg 3.67 kg Product Specification ※ ‘sccm’ and ‘slm’ is the flow unit at the standard condition (0℃, 101.3 kPa). ※ This specification is subject to change without prior notice. ▪Realized compact size through pilot method ▪Applied the surge protection circuit to reinforce the safety standard ▪Applied the temperature compensation circuit to maintain the accuracy against the environmental temperature change Product Description